ZIPLEVEL
®
can be used to record measurement data for creating tables,
proles, sections, contour or 3D maps. Press REC and MARK together for
2 seconds to enter or exit. REC will be ashing on the display while in the
Record Data function. Press REC and ZERO together for 2 seconds to clear
all data. Press HOLD momentarily to record each measurement. Press the
ZERO key for 2 seconds to back step and clear a previous measurement,
then momentarily press and release to clear additional measurements.
With each measurement, the display shows that measurement’s position
within a sequence (PXXX) and the sequence number (fraction digits). Press
MARK 2 seconds to start a new sequence. The display will ash ‘FULL’ with
each measurement when memory is within 20 measurements of being lled.
The number of remaining measurements will show in the fraction digits. A
PC can be connected to the serial port to store, graph or tabulate each
measurement as it is taken for an unlimited number of measurements. The
position display will show (FXXX) after the ZIPLEVEL
®
memory is full.
The REC DATA function can be used while in the CARRY function to record
data with each press of the HOLD key. CARRY data and normal data won’t
mix – storing one will delete all other data.
23 ▪ RECORD DATA