The RECord function eliminates extensive tabulation and computation re-
quired to average large numbers of readings. Now you can easily estimate
the slurry necessary to level an uneven concrete surface, the ll needed
below concrete or predict the graded level of a hilly lot (see illustrations).
You can also estimate the volume of a pile of dirt or the volume to ll a hole
by rst nding the difference between the average of readings every pace
around the edge of the pile or hole and the average of readings at every
pace criss-crossing the pile or hole. Volume = (difference of the two aver-
ages) X (estimated cross-sectional area of the pile or hole).
To enter the record function, press REC 2 seconds causing REC to appear
on the display. Momentarily press REC to display current reading, AVG (av-
erage), MIN (minimum) or MAX (maximum). Press HOLD momentarily to
include each of an unlimited number of readings in the computations.
Press REC 2 seconds to exit the Record function. Previously computed data
will be replaced with new data if you press the HOLD button after re-entry.